Fri - 15 Nov 2024     
Transmission Line Trainer

Product Description :

Amitec Transmission Line Trainer

TLA05

 Amitec Transmission Line Training System

TLA05

 Amitec Transmission Line Analyser

TLA05

Amitec TLA05 Technical Specifications:

Amitec Model TLA05 Transmission Line Analyzer has been

designed to help educators visualize standing waves on a

CRO and work on real transmission lines unlike most of the

transmission line trainers currently available for educational

purposes which use artificially simulated line modules with

lumped parameters. An exhaustive manual has been provided

with the system, which provides detailed experimental

procedure of the system.

* To study standing waves and observe maxima and

minima of a transmission line on a CRO.

* Uses actual coaxial lines rather than simulated ones.

* Appreciate significance of impedance matching.

* Measures VSWR, reflection coefficient, characteristic

impedance, velocity of propagation, dielectric constant

and signal attenuation in TDR.

* Study Time Domain Reflectometry.

* Study location and nature ofdiscontinuities, Open/short,

mismatched terminations, etc.

* Offers a complete view of the transmission line in analog

and digital domains, which is essential for complete

understanding of transmission line behavior.

Frequency range : 30-300 MHz typical LCD Display.

Level : 100mV p-p

Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB

Output Impedance : 50 Ohms

Scope out : X-Y output to scope

Characteristic Imp. : upto 900 ohms

Display : LCD

PRR Short range : 10MHz typical

Pulse width : <10ns typical

PRR Long range : 100KHz typical

Amplitude : 1V nominal

Output Impedance : 50 Ohms

A. Frequency Domain Analyzer

B. Resistive Impedance Analyzer

C. Time Domain Reflectometer

Accessories

E-Manual: Installation DVD for ease of Learning

List of Experiments TDR

List of Experiments FDR

Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms

parallel line with balun, lossy line, Tee connectors, ,Standard

load of 50 and 75 ohms, Various capacitive and inductive

loads, shorts, Operating manual, Mains cord

1. Introduction

2. To observe the open / short & terminated line.

3. To measure the characteristic impedance of a line.

4. To measure the velocity and dielectric constant

5. To measure the attenuation constant

6. To measure the VSWR, return loss

7. To observe the two sections joined with a connector

8. To observe the inductive coil Termination

9. To observe the t-line with a capacitor termination

10. To observe the t-line with a varying pulse width

11. To observe line with partial open and partial short

12. To observe the lossy transmission line

1. To setup the standing waves and observe the maxima

and minima on a CRO in real time.

2. To measure characteristic imped. &differentiate between

the matched and unmatched lines.

3. To study the attenuation characteristic of signal along a

transmission line and observe its variation with frequency

4. To study the effect of reactive loads

5. To study the difference between lossy and loss less

6. To study the physical dimensions & estimate its Zo

7. To study behavior of infinite and short lines.

8. To study the operation of balun transformer on 300 ohms

parallel line.

9. To study dielectric constant of insulator.

10. To study velocity of propagation & wavelength.

Product Specifications :

Category :Transmission-Line Components

Sub Category :

ID :P_90
Product ID :Transmission Line Training Sys
Product URL : www.amitec.co.in
Product URL Text : www.amitec.co.in
Cost :Low Cost
Model :TLA05
Product Download URL : www.amitec.co.in
Product Download URL Text : www.amitec.co.in
Details of Product Vendor
Name :Amitec Electronics ltd.
Web :www.amitec.co.in
Web Text :www.amitec.co.in
Phone :+919810193153,+91981
Fax :+91-120-4371276-26

  Privacy Policy

  Disclaimer

Copyright 2003-2024 rfdesign.info  

Website design by anandsoft.com