Product Description :
Microwave bench-Amitec Electronics Microwave Bench, Microwave trainers, antenna trainer kit, microwave trainers supplier, antenna trainer kit suppliers, microwave antenna trainers, microwave trainers manufacturer, microwave trainers India, microwave components manufacturer, antenna trainer kit exporters, antenna trainer kit India, waveguide components exporter, microwave part suppliers, waveguide components suppliers, waveguide components manufacturer, microwave waveguide instruments,magic tees, horns, x-band microwave benches, waveguide components, bends, twist, couplers, isolators, instruments, circulators, Gunn oscillator, elbows, flanges and subsystems, Microwave power meter 18 GHz, 40 GHz, X band spectrum analyser, MIC trainers till 18 GHz, Stealth trainer, Microwave signal sources upto 26 GHz, mmwave, submm wave solutions, PLL synthesized antenna trainers, DRO , Doppler radar trainers, Pulse radar tariner, FMCW radar trainer, UAV- Unmanned Aerial Vehicle,satellite communication trainers, VSWR meters, Gunn Power supplies, detectors till 40 GHz, Gunn oscillators till 94 GHz, Low cost X band Power meter,antenna trainers till 18 GHz, scalar network analyser till 18 GHz, dual and triple channel Microwave power meter, 3 GHz low cost vector network analyser, Maskless lithography, nanotechnology solutions,AFM, Transmission line analysers, low cost Site master for tower measurement, cable TDR, OTDR, directional couplers,anechoic chamber,supplier for sma, N, APC, K connectors, rogers, arlon,duroid etc,antenna analysis softwares, trainings on CST Microwave studio, IE3D for Mtech & phd scholars,Guidance on PhD in field of microwave, CDMa, Bluetooth, WLAN, BER testers, Wireless link design testing, customers include IITD- bharti school,YIG oscillators, Noise generators, 24 GHz spectrum analysers, Frequency upconverters and down converters, MICROWAVE TEST BENCH X BAND MWB Features: * All components are precious metal plated * Tested on HP network analyser 1. Digital Gunn Power supply It consists of a regulated DC Power supply and a square wave generator, to operate Gunn oscillator and PIN modulator Gunn Bias Voltage 0-10 V Current 0-750mA Modulation Frequency 900-1100Hz Modulation Amplitude 0-10V . 2. VSWR meter It consists of a calibrated high gain tuned amplifier for measurement of VSWR and relative Power levels. It is calibrated in VSWR and dB for square law of detector . Frequency 1KHz Bandwidth 100Hz Sensitivity 2uV 3. Gunn Oscillator A Gunn oscillator generates microwave frequencies using a Gunn diode. It is supplied with calibration giving frequency Vs. micrometer reading. Frequency range X band Power output 10dBm 4. PIN-diode modulator PIN diode modulator produces amplitude modulation of the CW output of Gunn oscillator for detection by VSWR meter. It consists of a PIN diode mounted inside a section of waveguide. Amplitude modulation 50% Insertion loss 2dB Technical Specifications 5. Variable attenuator A variable attenuator provides attenuation by varying the degree of insertion of a matched resistive strip into a wave guide. The variable attenuator is used to control a power level or to isolate a source from a load. Attenuation 0 to 20dB variable 6. Slotted line with matched Probe A slotted line is used to measure the amplitude and the phase of the standing wave pattern to determine the wavelength, standing wave ratio and the impedance of the waveguide transmission line. It has built in detector. Residual SWR 1.1 7. Waveguide matched detector The detector has a high sensitivity schottky diode mounted inside a wave guide. It is used for detection /demodulation of microwave signals. 8. Matched termination It is non reflective and absorptive termination matched to the waveguide. Return Loss >25dB 9. Slide screw tuner precision micrometer type It is used to match loads, detectors, or antennas to the characteristic impedance of the waveguide. The combination of the depth and the position of the probe causes reflection in the wave guide at a specific amplitude and phase. Microwave test bench MWB05 10. Wave guide Stands They are used to support the microwave components for setting up waveguide Test bench. 11. Shorting plate When measuring the wavelength inside of a wave guide. a shorting plate is used to create a short (zero impedance) at the open end of a wave-guide. 12. Fixed attenuator. The purpose of the fixed attenuator is to provide a fixed attenuation, isolation, padding etc. The attenuation is obtained by insertion of a thin conducting absorber into a straight portion of a standard waveguide. Attenuation 3dB 13. Magic-Tee (or Hybrid-Tee) A magic-Tee is a four port device where power incident on any arm splits equally between the two adjacent arms, but there is no power coupled to the opposite arm. The magic-Tee is an essential device in balanced mixers, automatic frequency control circuits and Impedance measurement circuits. 14. Directional coupler A directional coupler is consisted of two wave guides combined together and coupled by holes at the joining section. It is used to measure the VSWR or return loss of components. Coupling 10dB Directivity 30dB 15. Wave guide rigid rectangular straight section. It is a straight section of wave guide used in measurements of the wavelength and the phase velocity inside a wave guide. 16. Wave guide to Coaxial Adapter It provides a transition between a wave guide and a 50 ohm coaxial cable. It has low SWR with flat frequency response and low loss. 17. Pyramidal Horn Antenna It consists of a section of waveguide joined to a pyramidal section to concentrate the energy in a beam. Gain 16dB 18. Reflecting Panel It is used to reflect electromagnetic waves in free space when measuring free space wavelength. Accessories Mains Lead, BNC-BNC lead, BNC Technical Specifications EXPERIMENTS: 1. Introduction to waveguide components. 2. Gunn oscillator i) Measurement of current vs. voltage characteristic of Gunn diode. ii) Measurement of Gunn oscillator output power and supply voltage. iii) Measurement of Gunn oscillator output frequency and supply voltage. 3. Modulator and crystal detector i) Operation of PIN diode modulator. ii) Operation of crystal detector. iii) Measurement of square law characteristic of crystal detector. 4. Propagation modes, wavelength and phase velocity in a waveguide. i) Measurement of frequency of source. ii) Measurement of free space & guide wavelength and verify waveguide law. 5. Q and bandwidth of resonance cavity. i) Measurement of Q using power meter technique. ii) Measurement of Q using SWR method. 6. Power Measurement i) Direct Power Measurement ii) Measurement of Power using Directional Coupler. iii) Measurement of conjugate and Zo power. iv) Measurement of power of modulated signal. 7. VSWR and Reflection Coefficient by Standing wave and Double Minimum Method i) Measurement of low and medium range SWR. ii) Measurement of high range SWR. iii) Measurement of high range SWR using a calibrated attenuator. 8. Impedance Measurement i) Measurement of unknown Impedance of a load using smith chart. ii) To match an unknown impedance. 9. Waveguide Hybrid( Magic) Tee i) Measurement of Power division or Decoupling between H-arm and E- arm of a Magic Tee. ii) Measurement of Insertion loss of a Magic Tee. iii) Measurement of Return Loss of H arm of a Magic Tee. vi) Measurement of VSWR of ports of Hybrid (Magic) Tee 10. Properties of Directional Coupler i) Measurement of coupling factor. ii) Measurement of directivity. iii) Measurement of return loss of a load. iv) Measurement of Main line insertion loss. v) Measurement of VSWR of ports. 11. Fixed and Variable Attenuator i) Measurement of attenuation using the Power Ratio method. ii) Measurement of attenuation using the RF substitution method. iii) Measurement of low values of attenuation. iv) Measurement of VSWR and Insertion Loss. v) Measurement of Insertion Loss of attenuator. 12. To study a cavity resonator type frequency counter. 13. To study wave guide to coax transition. 14. Radiation pattern and Gain i) To study polar patterns and measure gain for the pyramidal horn antenna. 19. To establish a Microwave communication link. Optional : Power Meter MPM18 X Band Signal Generator DRO 10.5 GHz source Enter/Edit Using HTML Editor
|